Table 1 Limit of detection (LOD) and percentage of nondetects (ND) for 350 samples analyzed at the Wisconsin State Laboratory of Hygiene.

From: Decreased sex ratio following maternal exposure to polychlorinated biphenyls from contaminated Great Lakes sport-caught fish: a retrospective cohort study.

PCB congener (IUPAC*)

LOD (ng/mL)

% ND

PCB congener (IUPAC)

LOD (ng/mL)

% ND

PCB congener (IUPAC)

LOD (ng/mL)

% ND

#5/8

1.20

100

#56/60

0.35

100

#141

0.15

100

#6

0.65

100

#66/95

0.55

98.9

#146

0.20

80.3

#7/9

0.40

100

#70/76

0.25

100

#151

0.15

100

#15/17

060

100

#74

0.25

80.6

#167

0.25

99.4

#16/32

0.55

100

#77/110

0.25

100

#170/190

0.35

80.9

#18

0.35

100

#82

0.20

100

#171/202

0.15

96.0

#19

0.40

100

#84/92

0.55

100

#172/197

0.30

95.7

#22

0.50

100

#85

0.25

100

#174

0.20

100

#24/27

0.30

100

#87

0.20

100

#177

0.20

93.4

#26

0.25

100

#91

0.25

100

#178

0.35

96.6

#28/31

0.60

100

#97

0.15

100

#180

0.20

9.7

#33

0.25

100

#99

0.25

84.3

#182/187

0.10

39.3

#37/42

0.30

100

#101

0.30

100

#183

0.15

86.3

#40

0.30

100

#105/132/153

0.20

7.1

#185

0.15

100

#41/71/64

0.40

100

#118

0.20

57.3

#194

0.15

74.9

#44

0.30

100

#123/149

0.15

100

#195/208

0.10

92.3

#45

0.30

100

#128

0.25

100

#196/203

0.30

70.7

#46

0.40

100

#135/144

0.30

100

#199

0.15

99.7

#47/48

0.40

100

#136

0.30

100

#201

0.20

56.7

#49

0.25

100

#137/176

0.10

100

#206

0.15

91.5

#52

0.25

100

#138/163

0.25

10.8

   
  1. * International Union of Pure and Applied Chemistry Interference from contamination prevented determination of concentrations of these congeners in all but 1 sample. The one remaining sample was nondetectable for both congeners.